The Elcometer 266 revolutionizes high voltage DC testing of coatings porosity detection making it safer, easier and more reliable than ever before.
Elcometer 266 Features
![]() |
No need to use look up tables. Enter the test standard and the coating thickness and the gauge will automatically program the correct voltage. |
![]() |
Sensitivity to current can be manually preset or automatically adjusted by the gauge for partially conductive coatings. |
![]() |
The closed loop system ensures that the generated test voltage is accurately measured and continuously controlled, regardless of climatic conditions. |
![]() |
Interchangable probes handles are available, 5kV, 15kV and 30kV DC Versions |
![]() |
Bright LEDs on the handle, as well as a loud audible alarm, clearly indicate if the gauge is on (Red) and when a spark is detected (Blue). |
![]() |
Batteries are fully charged within 4 hours and provide up to 40 hours continuous use between charges. |
![]() |
Models 780, 785 & 790 Models 10/20 & 14/20 Compact DC & Compact Pulse |
![]() |
Large, backlit display enables easy viewing even in dark environments. When a flaw is detected the backlight also flashes. |
![]() |
The optional second hand grip is designed for two handed use without compromising its safety. Ideal for testing pipes and tank floors |
![]() |
The easy to use menu driven displays can be viewed in multiple languages for optimum versatility. |
Elcometer 266 Safety Features
![]() |
2-stage safety switch ensures that if the Elcometer 266 handle is not gripped, the handle will switch off. |
![]() |
To the user and has been specifically designed to meet standard EN61010. High voltage testing has never been safer. |
![]() |
The speaker on the gauge clearly emits a ticking noise to indicate that there is voltage at the handle. |
![]() |
A loud audible alarm is activated when a spark is detected. The beep volume can also be adjusted to ensure it can be heard - even in noisy environments. |
| Part Number | Description | ||
| D266----4 | Elcometer 266* | ||
| High Voltage Output Accuracy | ±5% or ±50V below 1000 Volts | ||
| Operating Temperature | 0°C to 50°C (32°F to 120°F) | ||
| Power Supply | Rechargeable lithium ion battery, fully charged within 4 hours | ||
| Measured Current Flow Accuracy | ±5% of full scale Output Current:0 - 100µA maximum | ||
| Typical Battery Life - Backlight Off (On) | DC5: 40 (20) hours | DC15: 20 (15) hours | DC30: 10 (8) hours |
| Instrument Case Dimensions | Waterproof, ABS case; 520 x 370 x 125mm (20.5 x 14.5 x 5”) | ||
| Weight | Base unit (including battery pack): 1.2kg (2.7lb) Handle: 0.6kg (1.3lb) | ||
| Certificate available | Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability | ||
| Packing List | Elcometer 266 DC Holiday Detector, lithium battery, curly connection cable for high voltage handle, 10m (32’) signal return lead, battery charger with 3 mains cables (UK, EUR and US), band brush, shoulder strap, tough plastic carry case and operating instructions | ||
*The Elcometer 266 does not include the probe handle; please select the required handle in the accessories
Can be used in accordance with:
ANSI/AWWA C213, AS 3894.1, ASTM C 536, ASTM C 537, ASTM D 4787, ASTM G 6, ASTM D 5162-B, ASTM G 62-B, BS1344-11,
DIN 55670, EN 14430, ISO 2746, JIS K 6766, NACE RP0274, NACE RP0188, NACE RP0190, NACE RP0490, NACE SP0188,
NACE SP0490