The Elcometer 319 Dewpoint Meter has been designed to measure and record all the relevant climatic parameters required to determine whether conditions are suitable for painting.
|
Can be used in accordance with:
|
|
|
BS 7079-B4
|
IMO MSC.215(82) |
| IMO MSC.244(83) | ISO 8502-4 |
| US Navy NSI 009-32 | US Navy PPI 63101-000 |
| FEATURES | STANDARD | TOP |
| Reading Parameters - RH, Ta, Ts, Td, Delta T, Tdb, Twb**, SH** | * | * |
| Statistics - Number of readings, standard deviation, mean, coefficient of variation, minimum, maximum | * | * |
| Dustproof & Weatherproof Gauge with Fully Sealed Sensors (Equivalent to IP66) | * | * |
| Integral Magnets - Secures the gauge to any ferrous metal object | * | * |
| High/Low Limits - Audible, visual, Red/Green LED alarms can be set against any or all parameters | * | * |
| Multi Language Menus | * |
* |
| Backlight - User selectable, brightness adjustment and timeout | * | * |
| K-Type Connector for External Measurement | * | * |
| Memory - With readings and statistics review | Last 10 records | 40,000 records in 999 batches |
| Manual Logging | * | * |
| Interval Logging | User defined time intervals between 1 second and 24 hours |
|
| USB & Bluetooth® Wireless Data Output | * | |
| ElcoMaster™ and ElcoMaster™ Mobile Software | * | |
| Part Numbers | G319----S | G319----T |
| Packing List | Elcometer 319 Dewpoint Meter, AA batteries (x2), wrist strap, carry case, calibration certificate, USB Cable*, ElcoMaster™ & ElcoMaster™ Mobile Software*and operating instructions | |
| * Elcometer 319 Top only ** Calculated Value | ||
| TECHNICAL SPECIFICATION | |||
| 1 | Range | Accuracy | Resolution |
| Air Temperature (Ta) | -20 to +80ºC (-4 to +176ºF) | ±0.5ºC (±1ºF) | 0.1ºC (0.1ºF) |
| Surface Temperature (Ts) | -20 to +80ºC (-4 to +176ºF) | ±0.5ºC (±1ºF) | 0.1ºC (0.1ºF) |
| External K-Type Thermocouple (Te) | -40 to +200ºC (-40 to +392ºF) | ±0.5ºC (±1ºF)*** | 0.1ºC (0.1ºF) |
| Relative Humidity (RH) | 0 to 100%RH | ±3%RH | 0.1% |
| Specific Humidity | 0 g/kg to 325 g/kg (0 gr/lb to 2275 gr/lb) |
±8% | 0.1 g/kg (0.1gr/lb) |
| Gauge & LCD Operating Temperature | -20 to +80ºC (-4 to +176ºF) | ||
| Power Supply | 2 x AA 1.5V Batteries or via USB Cable | ||
| Battery Life | Manual Mode: Greater than 40 hours (Backlight off) Interval Logging*: Up to 400 hours (1 reading every 10 minutes) |
||
| Dimensions | 180 x 75 x 35mm (7 x 3 x 1.4") | ||
| Weight | 300g (10.6oz) | ||
| * Elcometer 319 Top only *** Accuracy ±2ºC (±4ºF) when using Elcometer supplied probes | |||
| SPARES & ACCESSORIES | (Click Part Number to purchase) |
| Magnetic Surface Probe | T31920162-1 |
| Liquid Temperature Probe | T9996390- |
| USB Cable | T99921325 |