| T99911135 | Rite-Lok MC1500 Adhesive |
| T1089646- | Standard Flat Dolly 19.4mm (0.76”) |
Loading... Please wait...Link: Datasheet in PDF | Instruction Manual
The Elcometer 108 Hydraulic Adhesion Tester is an extremely versatile gauge which can be used for many adhesion requirements. Tests can be made on flat or curved (concave and convex) surfaces.
The Elcometer 108 is the ideal gauge for coatings on Tanks, Pipelines, etc.
Elcometer Digital Adhesion Gauge features:
The Elcometer 108 can be used with convex and concave dollies, making this the gauge for adhesion of coatings on all pipelines including those with small diameter, tanks and other curved surfaces. There is a wide range of curved dollies available, each designed for a specific range of curvature.
Concave and convex dollies designed to meet specific curvatures are available upon request.
| Part Number | Description |
| US 110V | |
| F108---1C | Elcometer 108/1 Hydraulic Adhesion Tester - Analog Dial Gauge |
| F108---2C | Elcometer 108/2 Hydraulic Adhesion Tester - Digital Gauge |
| Analogue Instrument Range | Operating: 0 - 18MPa (0 - 2600psi) |
| Analogue Instrument Accuracy | ±1MPa Metric Scale; 150psi (Imperial Scale) |
| Digital Instrument Range | Operating: 0 - 18MPa (0 - 2600psi) |
| Digital Instrument Accuracy | ±3% or 60psi (whichever is the greater) |
| Outside Diameter | 19.4mm (0.76”) |
| Inside Diameter | 3.7mm (0.15”) |
| Area | 284mm² (0.44sq.inch) |
| Certificate available | Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability. |
| Packing List | Elcometer 108, ABS carry case, 5 flat dollies, 5 nylon plugs, MC1500 quick curing adhesive, dolly cleaning tool, heating tongs |
Can be used in accordance with:
ASTM D 4541, ISO 16276-1, NF T30-606