Loading... Please wait...Links: Technical Specification | Data Sheet | Instruction Manual
Chloride Salts left on the surface before the first coat is applied can result in the coating system being forced off the surface by corrosion or blistering before the full life of the coating has been reached.
To ensure that the chloride has been removed it is essential that the surface is tested before the coating is applied.
Test method:
The Elcometer 134 Salt Detection Kit for Blast Cleaned Surfaces is simple and convenient to use with its three-step process
|
Elcometer 134A Chloride Ion Test Kit for Abrasives |
Elcometer 134S Salt Detection Kit for Blast Cleaned Surfaces |
Elcometer 134W Chloride Ion Test Kit for Water/Liquids |
|
|
Measuring Range |
1– 50ppm (µg/cm²) |
1 – 60ppm (µg/cm²) |
10 – 2000ppm (µg/cm²) |
|
Scale Resolution |
1ppm |
1ppm |
10ppm |
|
Sampling Time |
1.5 minutes |
1.5 minutes |
1.5 – 4 minutes |
Tests per Box |
4 |
5 |
5 |
|
Colour Change |
Pink to White |
Pink to White |
Pink to White |
|
Storage Conditions |
25ºC (77ºF) |
25ºC (77ºF) |
25ºC (77ºF) |
|
Kit Weight |
367g (13oz) |
250g (9oz) |
208g (7oz) |
|
Kit Dimensions |
185 x 125 x 110mm (7 x 5 x 4.5") |
185 x 125 x 110mm (7 x 5 x 4.5") |
185 x 125 x 110mm (7 x 5 x 4.5") |
|
Part Numbers |
E134----2 |
E134----1 |
E134----3 |
|
The Elcometer 134 units do not require the use of needles or contain mercury. |
|||
|
Can be used in accordance with:
|
|
|
ISO 8502-6
|
IO DIS 8502-9 |